Skip to content
Press Equals

Mini Split Size Calculator

Size a ductless mini split for up to four rooms: the BTU each room needs, the indoor head to buy and the outdoor unit size.

Result

A rule-of-thumb size. A contractor's Manual J load calculation is more exact for drafty, very sunny or well-insulated homes.

Outdoor unit

9,000 BTU (0.75 tons)

Total cooling needed
7,500BTU/hr
Total in tons
0.63tons
Indoor heads
1

Room by room

RoomSize (sq ft)NeededHead to buy
Room 13007,500 BTU9,000 BTU
Room 17,500 BTU
A 9,000 BTU (0.75 tons) outdoor unit with 1 indoor head.

What this calculator does

This calculator sizes a ductless mini split for up to four rooms. It gives the cooling each room needs in BTU per hour, the standard indoor head to buy for each room, and the outdoor unit that can run them all.

How to use it

  1. Enter the square footage of each room you want to cool (length × width). Leave unused rooms at 0.
  2. Enter the ceiling height. Rooms taller than 8 ft need more cooling.
  3. Pick your climate and how much sun the rooms get.

How it's sized

Each room needs 20 to 35 BTU per square foot depending on climate: 20 in a cool climate, 25 moderate, 30 warm and 35 hot. Following ENERGY STAR, a heavily shaded room needs 10% less and a very sunny room 10% more. Ceilings over 8 ft scale the load up in proportion.

Indoor heads come in standard sizes (6,000, 9,000, 12,000, 15,000, 18,000, 24,000, 30,000 and 36,000 BTU), so each room gets the smallest head that covers it. The outdoor unit is sized to the total load, because the rooms rarely all need full cooling at once.

How to calculate mini split size

  • Room load (BTU/hr) = square feet × BTU per square foot × sun factor × (ceiling ÷ 8 when over 8 ft)
  • Tons = BTU ÷ 12,000

Examples

Example 1: One bedroom. A 300 sq ft room in a moderate climate needs 7,500 BTU per hour. A 9,000 BTU head and a single-zone outdoor unit cover it: 9,000 BTU (0.75 tons).

Example 2: Three rooms in a warm climate. Rooms of 350, 200 and 150 sq ft need 21,000 BTU in all, across 3 indoor heads. A 24,000 BTU (2 tons) multi-zone outdoor unit runs them.

Example 3: A sunny room with tall ceilings. 400 sq ft with 10 ft ceilings and lots of sun needs 13,800 BTU, so it takes a 15,000 BTU head and an 18,000 BTU (1.5 tons) outdoor unit.

Tips and common mistakes

  • Bigger isn't better. An oversized head cools the room before it dries the air, so it short-cycles and feels clammy.
  • Kitchens run hot. Add about 4,000 BTU for a kitchen, or treat it as a sunny room.
  • Get a Manual J for a whole-home system. This is a rule of thumb. A contractor's load calculation counts insulation, windows and air leaks.
  • Sizing one window unit or portable AC? The BTU calculator takes a room's length and width.

How we check this calculator

  • Tested against 5 reference answers worked from published sources or by hand,such as “700 sq ft × 30 BTU in a warm climate”.
  • All 3 worked examples in the article above are run through this calculator, so the two can't disagree.
  • Every input is tried at its smallest and largest values and with random numbers, and must never crash or show a broken number.
  • These checks run automatically before any change goes live.

Spotted a wrong number? Tell us and we'll fix it. See how the calculators are tested.

Updated