Size a room air conditioner by the floor area you want to cool: roughly 20 to 25 BTU an hour per square foot, then adjust for sun, people and a kitchen. Buying the right size matters more than buying a big one, because an oversized unit cools the air without drying it.
Start with the room's area
Measure the room's length and width in feet and multiply. A 15 × 20 ft room is 300 square feet. For an L-shaped room, split it into rectangles and add them; the square footage calculator helps.
The ENERGY STAR sizing chart
ENERGY STAR's chart gives the capacity needed for rooms with 8-foot ceilings (ENERGY STAR):
| Area to cool (sq ft) | Capacity (BTU per hour) |
|---|---|
| 100 up to 150 | 5,000 |
| 150 up to 250 | 6,000 |
| 250 up to 300 | 7,000 |
| 300 up to 350 | 8,000 |
| 350 up to 400 | 9,000 |
| 400 up to 450 | 10,000 |
| 450 up to 550 | 12,000 |
| 550 up to 700 | 14,000 |
| 700 up to 1,000 | 18,000 |
| 1,000 up to 1,200 | 21,000 |
| 1,200 up to 1,400 | 23,000 |
| 1,400 up to 1,500 | 24,000 |
| 1,500 up to 2,000 | 30,000 |
| 2,000 up to 2,500 | 34,000 |
Adjust for your room
ENERGY STAR's adjustments:
- Heavily shaded room: reduce capacity by 10%.
- Very sunny room: increase capacity by 10%.
- More than two people regularly in the room: add 600 BTU for each extra person.
- Kitchen: add 4,000 BTU.
For example, a sunny 300 sq ft living room where four people watch TV: 8,000 + 10% = 8,800, plus 2 × 600 = 10,000 BTU.
Ceiling height and climate
The chart assumes 8-foot ceilings, and ENERGY STAR suggests a higher capacity for taller rooms. A hot climate adds load too.
The BTU calculator uses a rule of thumb of 25 BTU per square foot and scales it for ceiling height and climate. For the 15 × 20 ft room (300 sq ft) with 8 ft ceilings in a moderate climate, it gives 7,500 BTU an hour, between the chart's 7,000 and 8,000 rows.
With 10-foot ceilings, the same room needs about 9,400 BTU.
In a hot climate it's about 10,500 BTU, or 0.88 tons. One ton of cooling is 12,000 BTU an hour.
Why bigger isn't better
ENERGY STAR warns that "if the unit is too large, it will cool the room before it has a chance to remove the humidity", leaving the room damp and clammy. An oversized unit also "costs more to purchase, wastes energy and does not provide better cooling."
Units come in set sizes, much like the rows of the chart. Work out what the room needs, then pick the nearest size at or just above it.
Cooling more than one room
A window unit cools the room it's in. For several rooms, a ductless mini-split uses one outdoor unit and a head in each room, each sized for its own room. The mini-split size calculator adds up the rooms and suggests the head and outdoor unit sizes. Whole-house central air needs a load calculation from an HVAC contractor, which accounts for insulation, windows and ductwork.
Check your room
Measure the room, then put the length, width, ceiling height and climate into the BTU calculator. Compare the answer with the chart above and round up to the next unit size.